Temperature control units for jacketed reactors: from small reactors to more than 2,000 litres
Chemical reactor jackets usually withstand a maximum of about 3 bar. MARSE controls temperature and pressure in jacketed reactors from small units up to production reactors of more than 2,000 litres, with water or oil, from low temperatures up to 300 °C.
- Jacket
- ≈ 3 barusual maximum pressure
- Volume
- > 2,000 lproduction reactors
- Temperature
- Up to 300°Cfrom low temperatures
- Fluid
- Water or oildepending on the process

The case at a glance
- Jacket pressure
- Usual maximum of about 3 bar.
- Volume
- From small reactors to more than 2,000 litres.
- Temperature
- From low temperatures up to 300 °C.
- Fluid
- Water or oil, depending on the process.
- Pressure kit
- Pump with frequency inverter, expansion vessel and air vents.
The process and the initial problem
A jacketed or glass-lined reactor has to follow the temperature profile of each batch: heat to start the reaction, hold, and cool when the reaction releases heat. All of this without exceeding the maximum jacket pressure, which in many reactors is around 3 bar.
Pressure peaks occur during abrupt start-ups, valve hammer or when cold oil is circulated. A pressure surge can damage the glass lining or deform the jacket. That is why, in addition to temperature, the temperature control unit has to manage pressure.
Challenge and solution
A pressure surge can crack the glass lining or deform the jacket.

- Heat to start the reaction and cool when it releases heat
- Never exceed the maximum jacket pressure
- Peaks caused by valve hammer, abrupt start-ups or cold oil


- Pump with frequency inverter that holds a pressure setpoint
- Expansion vessel and automatic air vents
- Batch curve followed without overshoot
Why a MARSE temperature control unit in this case
For the process engineer
- Heating and cooling PID with ramps: the batch curve without overshoot.
- Range from low temperatures up to 300 °C, with water or oil.
- Experience with laboratory reactors and production reactors of more than 2,000 litres.
- Logging of temperature, pressure and flow for each batch.
For the maintenance manager
- Pressure kit: pump with frequency inverter that holds a pressure setpoint.
- Expansion vessel and automatic air vents.
- Soft start-ups: no pressure surges that shorten the life of the reactor.
- Magnetic pump without mechanical seal from 140 °C.
Technical keys
- Respecting the 3 barJacket pressure always below its maximum.
- From small to very largeUp to production reactors of more than 2,000 litres.
- The full rangeFrom low temperatures up to 300 °C.
- No pressure surgesPump with frequency inverter, expansion vessel and air vents.
Result
Frequently asked questions
What pressure can a reactor jacket withstand?
In many jacketed reactors the maximum is around 3 bar. The temperature control unit must always work below that value.
What size of reactor can a MARSE temperature control unit handle?
From small reactors up to production reactors of more than 2,000 litres.
How are pressure surges avoided?
With a pressure kit: pump with frequency inverter, expansion vessel and automatic air vents, plus controlled temperature ramps.
Equipment and technology
Other success stories

A standardised injection moulding plant with more than 100 temperature control units
View case →
A 1997 MARSE MTR-36 comes back to the factory
View case →