Home›Success stories›Cleanroom reactors without exceeding their maximum pressure
Chemicals · Aerospace

Cleanroom reactor thermoregulation without exceeding their maximum pressure

In chemical reaction cleanrooms and in aerospace composites, the temperature control unit has to follow the profile of each batch without putting the reactor at risk. MARSE temperature control units are configured to always work below the maximum pressure the reactor can withstand, usually with oil, and meet the heating and cooling times required by the customer.

SectorChemicals and aerospace
Pressure
Below the maximumthe reactor can withstand
Fluid
Oilwater in some cases
Control
T and timesfor heating and cooling
Circuit
Closedno contact with the room
Atemperador MARSE junto a un reactor encamisado en una sala blanca
Jacketed reactor in a cleanroom, thermoregulated with a MARSE temperature control unit.

The case at a glance

Sector
Chemicals and aerospace
Constraint
The reactor never exceeds its maximum allowable pressure.
Fluid
Oil in most cases; water in some.
Control
Temperature and heating and cooling times.
Circuit
Closed: the fluid does not touch the room atmosphere.

The process and the initial problem

A jacketed reactor has a maximum allowable jacket pressure. The temperature control unit must heat to start the reaction, cool when the reaction releases heat and follow the profile of each batch, always without exceeding that limit.

The choice of fluid is key: water above 100 °C needs pressure so as not to boil (≈ 2 bar absolute at 120 °C and ≈ 3.6 bar absolute at 140 °C). With pressure-limited reactors, oil makes it possible to reach high temperatures at low pressure, which is why it is the usual fluid in these cases.

Challenge and solution

Heat to start the reaction, cool when the reaction releases heat, without ever overstressing the reactor.

The challenge
  • Reactors with a limited maximum pressure
  • Temperature profiles and cycle times set by the customer
  • Clean, controlled environment
The solution
  • Configuration that always works below the maximum pressure
  • Oil as the usual fluid because of that pressure limitation
  • Heating and cooling within the required times

Why a MARSE temperature control unit in this case

For the process engineer

  • Configuration that always works below the reactor's maximum pressure.
  • Heating and cooling PID with auto-tuning: the batch profile, without overshoot.
  • Heating and cooling times matched to what the process requires.
  • Traceability: temperature, pressure and flow graphs, and data via USB.

For the maintenance manager

  • Closed circuit: the fluid does not come into contact with the room.
  • Magnetic pump without mechanical seal from 140 °C: no more of the most common leak point.
  • Compact units on wheels, with controls on the front.
  • Pressure and temperature alarms to protect the reactor.

Technical keys

  1. No stress on the reactorIt always works below its maximum allowable pressure.
  2. Oil by defaultHigh temperature at low pressure; water when the process allows it.
  3. Cycle timesHeating and cooling within the required times.
  4. Clean roomClosed circuit and compact units.

Result

Reactor protectedIts maximum pressure is never exceeded.
Tailor-made cyclesThe times the customer requires.
Clean roomClosed circuit.

Frequently asked questions

Why is oil used in cleanroom reactors?

Because oil reaches high temperatures at low pressure, whereas water above 100 °C needs pressure so as not to boil. With pressure-limited reactors, oil is the usual choice.

How is the reactor protected?

The temperature control unit is configured to always work below the maximum pressure the reactor can withstand, with pressure and temperature alarms.

Can the heating and cooling times be controlled?

Yes: the heating and cooling PID control follows the cycle times the process requires.

Equipment and technology

Other success stories

← All success stories
Do you have a similar process?Tell us what you need to solve and we will propose the right unit.
Talk to a specialist

Cleanroom reactor thermoregulation without exceeding their maximum pressure

Equipment with marking EC · European conformity
MARSE
Privacy Summary

This website uses cookies to offer you the best possible user experience. Cookie information is stored in your browser and performs functions such as recognizing you when you return to the website and helping the computer understand which sections of the website you find most interesting and useful.