Home›Success stories›9 mould circuits controlled with MARSE Flow Basic
Injection moulding

Flow control in 9 mould circuits with MARSE Flow Basic

A passive 9-circuit manifold was distributing flow blindly. A 9-circuit MARSE Flow Basic, mounted on the mould, measures and regulates each circuit and raises an alarm as soon as one loses flow.

SectorPlastic injection
Equipment
MARSE Flow Basicflow control on the mould
Circuits
9one line and one valve per circuit
Measurement
Flow, T and Pin each circuit
Quality
Per-channel controlalarms and logging
De manifold pasivo a control de caudal MARSE Flow Basic de 9 circuitos en un molde
From the passive manifold to the 9-circuit Flow Basic, mounted on the mould.

The case at a glance

Circuits
9, one line and one valve per circuit.
Equipment
MARSE Flow Basic, mounted on the mould.
Measurement
Flow, temperature and pressure of each circuit.
Regulation
Manual or proportional valves.
Aim
Per-channel quality control and fewer rejects.

The process and the initial problem

A passive supply and return manifold distributes the flow from the temperature control unit among the mould circuits, but the distribution depends on the pressure drop of each hose, not on what each zone needs.

When a circuit gradually clogs with limescale or dirt, its flow drops little by little and its zone of the mould heats up. With a passive manifold there is no signal at all: the problem is discovered when rejects appear.

Before and after

The distribution no longer depended on the length of each hose, but was adjusted to what each cavity needs.

Before
  • Passive supply and return manifold, 9 circuits
  • Distribution according to the resistance of each hose
  • A blockage caused by limescale or dirt was detected when rejects appeared
After
  • 9-circuit Flow Basic mounted on the mould
  • Labelled lines, one valve per circuit
  • Each circuit brought to its target flow

Why the MARSE Flow Basic in this case

For the process engineer

  • Each circuit brought to its target flow, not to whatever the hose allows.
  • Flow, temperature and pressure of all 9 circuits in view.
  • Recipes per mould to repeat the start-up.
  • Data logging to document the process.

For the maintenance manager

  • Per-circuit alarm when the flow drops: the blockage is seen before the reject.
  • Labelled lines and one valve per circuit: locating a problem is immediate.
  • Mounted on the mould, synchronised with the MARSE temperature control unit.
  • 7″ touch screen with alarms and history.

Technical keys

  1. See every circuitAll 9 circuits, measured one by one.
  2. Adjust every circuitManual or proportional valves per line.
  3. Detect blockagesDropping flow triggers an alarm.
  4. RepeatSettings saved per mould.

Result

Per-channel controlEvery circuit, monitored.
Fewer rejectsBlockages are spotted in time.
Repeatable start-upsRecipes saved per mould.

Frequently asked questions

What is the difference between a passive manifold and the MARSE Flow Basic?

The manifold only distributes the flow; the Flow Basic measures and regulates each circuit, with alarms, data logging and recipes per mould.

How does it detect a limescale blockage?

It measures the flow of each circuit: when it falls below its range, an alarm is triggered for that circuit.

How many circuits does it support?

From 2 to 12 per unit; in this installation, 9.

Equipment and technology

Other success stories

← All success stories
Do you have a similar process?Tell us what you need to solve and we will propose the right unit.